Product Specification:
  • Place Of Origin : Shenzhen, Guangdong
  • Model : SR-803-2
  • Material : ABS
  • Operating voltage : AC220V
  • The warranty time : 2 yesrs
See Price
  1. Product Details

SUMRING SR-803-2 AC220V hardwired photoelectric smoke and NTC heat combined fire detector

1. Key Features of SUMRING SR-803-2 Smoke Heat Detector

Tired of frequent battery replacement for battery-operated fire alarms? Our SUMRING SR-803-2 hardwired smoke heat detector connects straight to AC220V 50Hz mains power, delivering non-stop round-the-clock fire safety protection without power failure risks. With low power consumption design, the detector runs stably in harsh environments ranging from -10°C to +55°C, tolerating up to 90% non-condensing relative humidity. Its compact Φ100mm × 54mm ABS flame-retardant plastic body enables simple ceiling installation with a maximum mounting height of 3.5 meters, covering a detection area of up to 20 square meters per unit.

220V mains powered wired fire alarm sensor low power consumption wide temperature range

2.Complete Technical Specifications of SR-803-2 Hardwired Fire Alarm

Technical Specifications

Model number

SR-803-2

Product Name

AC220V Hardwired Smoke Heat Composite Detector

Working Voltage

AC 220V 50Hz

Sensing Type

Photoelectric Smoke + NTC Heat Dual Sensor

Signal Output

NO / NC Optional Relay Switch Signal

Alarm Mode

Audible Buzzer + LED Flashing Visual Alarm

Special Function

Auto Reset, Self-test Function, Dustproof & Insect-proof, Anti-white-light Metal Shield

Production Craft

SMT Automated Welding Circuit

Dimension

Φ100*54mm, Mounting Hole Spacing 6cm

Max Detection Area

≤20 Square Meters Per Unit

Material

Flame-retardant ABS

Max Installation Height

≤3.5 Meters

Smoke Sensitivity

0.1~0.3dB/m

Alarm Sound Level

≥80dB at 3 Meters

Reset Function

Manual Reset Button

Operating Environment

Temp: -10℃ ~ +55℃; Humidity: < 95% RH (Non-condensing)

Trigger Temperature

54°C ~ 65°C

Humidity Resistance

≤90%RH (Non-condensing)

Type

Non-coded Wired Fire Alarm Detector

Supply Type

Factory Direct Wholesale, Bulk Project Supply, Sample Available

roduct Dimensions

100mm x 54 mm

220V mains powered wired fire alarm sensor low power consumption wide temperature range

3 .Product Advantages

  • Dual Photoelectric Smoke & NTC Heat Sensing: Detects both smoldering smoke and abnormal high temperature, triggers alarm at 54℃–65℃ for dual fire hazard prevention.
  • Dual Alarm Indication: ≥80dB loud audible buzzer plus flashing LED light, delivers clear visual and audio warning signals.
  • Optional NO/NC Relay Switch Signal Output: Compatible with fire alarm control panels for centralized fire monitoring systems.
  • Multiple Smart Safety Functions: Built-in self-test function for regular equipment health checks, auto reset design for easy post-alarm recovery, dustproof and insect-proof internal structure to avoid false alarms.
  • Strong Anti-Interference Design: Metal anti-white-light shielding structure and SMT automated welding circuit eliminate light interference and guarantee stable long-term operation.
  • Durable Flame-Retardant ABS Material: High-temperature resistant, fire-proof plastic housing improves service life and safety. 
  •  

4 Wide Application Scenarios for AC220V Mains Smoke Heat Sensor

English This AC220V hardwired smoke heat composite detector is widely applicable to commercial and residential buildings: Hotel guest rooms & public areas, office buildings, storage warehouses, apartment residential buildings, shopping malls and engineering construction fire safety projects.

220V mains powered wired fire alarm sensor low power consumption wide temperature range

5 .Supply Advantage

English We support factory direct wholesale, large-scale engineering bulk supply and sample test orders. Stable stock, reliable product quality and complete technical parameter documentation are available for all global buyers and fire engineering contractors.

 

FAQ AC 220V wired smoke & heat detector SR-803-2

Q: What sensors does this detector use?
A: Photoelectric smoke + NTC heat dual sensor with MCU chip, metal anti-interference shield.

Q: Does it have relay output and auto reset?
A: Optional NO/NC relay output, auto reset after hazard clear, plus self-test function.


Q: What’s the installation coverage?
A: Max 3.5m mounting height, single unit covers ≤20㎡, install on ceiling away from vents.

Q: Where can this detector be used?
A: Hotels, offices, warehouses, apartments and all construction engineering projects.

Q: Do you support customization and samples?
A: OEM&ODM available, accept bulk project orders and provide test samples quickly.

Q: What’s your product advantage over common smoke detectors?
A: Dual sensor, stable SMT circuit, auto reset & self-test; ordinary ones only single sensor with poor stability.

220V mains powered wired fire alarm sensor low power consumption wide temperature range

220V mains powered wired fire alarm sensor low power consumption wide temperature range

220V mains powered wired fire alarm sensor low power consumption wide temperature range

Write us

Welcome to our company website, thank you for your letter, we will give you a reply in the first time, would you please leave your information and contact way!

>> Drag slider validation